China SmartGen HGM9510 Controller Performance and Characteristics
by Starlight Generator dieselgeneratortechHGM9510 controller is
designed for manual/auto parallel system generators with similar or different
capacity. Additionally, it is suitable for single unit constant power output
and mains paralleling. It allows automatic start/stop, parallel running, data
measurement, alarm protection as well as remote control, remote measurement and
remote communication function. It fits with LCD display, optional Chinese,
English and other languages interface, and it is reliable and easy to use.
Performance
and Characteristics
1. With ARM-based 32-bit
SCM, high integration of hardware and more reliable;
2. 480x272 LCD with
backlight, multilingual interface (including English, Chinese or other
languages) which can be chosen at the site, making commissioning convenient for
factory personnel;
3. Improved LCD
wear-resistance and scratch resistance due to hard screen acrylic;
4. Silicon panel and
push buttons for better operation in high/low temperature environment;
5. RS485 communication
port enable remote control, remote measuring, remote communication via ModBus
protocol.
6. Fitted with CANBUS
port and can communicate with J1939 genset. Not only can you monitoring
frequently-used data (such as water temperature, oil pressure, engine speed,
fuel consumption and so on) of ECU machine, but also control start, stop,
raising speed and speed droop via CANBUS port.
7. Suitable for 3-phase
4-wire, 3-phase 3-wire, single phase 2-wire, and 2-phase 3-wire systems with
voltage 120/240V and frequency 50/60Hz;
8. Collects and shows
3-phase voltage, current, power parameter and frequency of Bus/mains.
9. For Bus, controller
has loss of phase and phase sequence wrong detection functions; For generator,
controller has over voltage, under voltage, over frequency, under frequency,
over current, over power, reverse power, loss of phase, phase sequence wrong
detection functions;
10. Synchronization
parameters: Voltage Difference Between Bus and Mains, Frequency Difference
Between Bus and Mains, Phase Difference Between Bus and mains;
11. Multiple running
modes in auto state: with load running, off load running, demand parallel
running;
12.Ramp on and ramp off
function;
a. 3 fixed sensors
(temperature, oil pressure and liquid level);
b. 2 configurable
sensors can be set as sensor of temperature, oil pressure or fuel level;
13. More kinds of curves of temperature, oil pressure, fuel level can be used directly and users can define the sensor curves by themselves;
14. Precision measure
and display parameters about Engine,
Temp. (WT) °C/°F (unit) both be displayed
Oil pressure (OP) kPa/psi/bar(unit) all be displayed
Fuel level (FL) %(unit)
Speed (SPD) r/min(unit)
Battery Voltage
(VB) V (unit)
Charger Voltage
(VD) V (unit)
Hour count (HC) can
accumulate Max. 65535 hours.
Start times can
accumulate Max. 65535 times
15. Protection:
automatic start/stop of the gen-set, ATS(Auto Transfer Switch) control with
perfect fault indication and protection function;
16. All output ports are
relay output;
17. Parameter setting:
parameters can be modified and stored in internal EEPROM memory and cannot be
lost even in case of power outage; most of them can be adjusted using front
panel of the controller and all of them can be modified using PC via USB or
RS485 ports;
18. Multiple crank
disconnect conditions (speed sensor, oil pressure, generator frequency) are
optional;
19. Widely power supply
range DC(8~35)V, suitable to different starting battery voltage environment;
20. Event log, real-time
clock, scheduled start & stop generator (can be set as start genset once a
day/week/month whether with load or not);
21. Accumulative total
run time and total electric energy of A and B. Users can reset it as 0 and
re-accumulative the value which make convenience to users to count the total
value as their wish.
22. Can control engine
heater, cooler and fuel pump.
23. With maintenance
function. Actions (warning, trip and stop, shutdown) can be set when
maintenance time out;
24. All parameters used
digital adjustment, instead of conventional analog modulation with normal
potentiometer, more reliability and stability;
25. IP55 waterproofness
level can be achieved with the help of rubber-ring gasket between shell and
control panel.
26. Metal fixing clips
enable perfect in high temperature environment;
27. Modular design,
self-extinguishing ABS plastic shell, pluggable terminal, built-in mounting,
compact structure with easy installation;
Sponsor Ads