Performance and characteristics


For more than half a century, high-voltage generator sets have gradually spread from the military industry to other sectors of the national economy, mainly due to the following performance characteristics of its high voltage synchronous generators (hereinafter referred to as high voltage generators or generators).


1. High output voltage


According to the relevant national standards, the line voltage of the rated output of the high voltage generator set is actually the line voltage of the high voltage generator output of 10KV. The rated output line voltage of the low-voltage generator set. Actually the line voltage of the low voltage generator output is 400V. the output voltage of the high voltage generator is 25 times higher than that of the low voltage generator.

 

2. Small output current

 

The power supply capability of the generator is characterized by its rated capacity SH=1.73UHIH. It defines the rated apparent power SH available to the generator with a rated power factor of 0.8 when the rated line current of the nominal line voltage UH is fed to the load is IH.

 

The rated apparent power that the low voltage generator can output is SHO, and the rated apparent power output that the other high-voltage generator can output is also SHO. Then there is (high-voltage power generation) 1.73UHGIHG = 1.73UHDIHD (low voltage generator). At this time, the ratio of the line current IHG output by the high voltage generator to the output line current IHD of the low voltage generator is

 

It can be seen that the same rated apparent power is output, and the line current supplied by the high-voltage generator is only one-fifth of that of the low-voltage generator. The current is small, the loss of electric energy on the transmission line is small, and the cross-sectional area of the transmission and distribution cable can be much smaller, which is beneficial to long-distance transmission and can save copper.

 

3. Strong rotor field

 

The high-voltage generator can obtain a rotor magnetic field and a magnetic flux Φ that are several to several times stronger than the low voltage generator by increasing the number of turns of the rotor winding coil and then direct current of the input coil (referred to as the excitation current). the excitation current comes from the generator automatic voltage regulation system consisting of a rotary rectifier, a brushless excitation generator and an automatic voltage regulator. The system links the rotor magnetic field flux Φ and the high voltage generator output voltage U with a negative feedback logic. If the decreases due to load fluctuations, the control system increases Φ and causes U to rise. It not only provides a large excitation current to the rotor winding to generate strong magnetic field and magnetic flux Φ, which creates conditions for the generator to output high voltage, and also automatically stabilizes the output voltage of the high voltage generator.

 

4. The number of turns in the stator winding is large

 

The more the number of turns of the coil, the stronger the induced electromotive force generated when the magnetic field cuts its motion. This is the basic principle of the generator. The high voltage generator has small current, and the wires used in the stator winding coil are much thinner than the low voltage generators. This facilities the increase of the number of turns in the stator windings. According to the design requirements, the parameters of the stator winding coil of the high voltage generator with different rated output power, the wire diameter, the size and shape of each turn are not the same. However, in general, the number of turns of the coils in the winding of the high voltage generator stator is generally several times to ten times more than that of the low voltage generator.

 

The number, shape, length or diameter of the grooves in the stator embedded in these windings are also manufactured according to the performance requirements of high voltage generators. Usually, the stator is also provded with a ventilation and heat dissipation groove and a temperature sensor to ensure that the temperature rise of the stator during operation meets the design requirements.

 

5. Neutral grounding is not normal

 

10KV high voltage generators are usually load-feed line voltages for delta-connected loads. Generally, the neutral line is not grounded. However, in order to protect the generator or to meet some special needs, the neutral line needs to be grounded through the resistor cabinet and the contactor cabinet. This is because leakage or short circuit in any of the windings theselves or their transmission lines causes the currents of the three windings to be unbalanced to generate a neutral current. The resistor cabinet not only prevents the surge of current, but also provides real-time varying voltage data for the detection control device. The measurement and control device studies the neutral voltage and automatically regulates the high voltage generator to operate outside the damage curve, although there is a neutral current but does not exceed the tolerance. Otherwise the command will be stopped to protect the high voltage generators.

 

6. High maintenance requirements

 

The high voltage generator belongs to the high voltage electrical equipment above 10KV. Its generator room, power distribution room, control cabinet, feeder cabinet, measuring cabinet, transmission and distribution cable, etc. Should meet the relevant national standards, in order to lay a good job for safety production. Because the use and maintenance of high voltage equipment is strict, personnel in management or control should be trained in high voltage electrical professional and have high voltage electrical operation qualifications, such as high voltage electrical. On the work, especially when handling and testing high voltage equipment on site, it is necessary to wear protective tooling, strictly in accordance with the process and specifications.