What are the specifications of the ventilator?

by Anisha Patil HPD

A ventilator is a machine that supports or takes over the breathing process, pumping air into the lungs. Persons who stay in intensive care units (ICU) may want the support of a ventilator made by Ventilator Manufacturers. This comprises people with severe COVID-19 indications.  


Facility to Measure and display

Understanding ventilator screens may be frightening for novices, but the data are fairly humble despite being obtainable slightly differently on the screens of each mechanical ventilator brand. There are a few key facts to recall when reviewing ventilator screens. 


(1) The standards set by clinicians are usually found on the bottom of the canopy. The patient’s rejoinder is situated at the top of the screen. 


(2) Information is provided in both numerical and graphical settings on the screen. 


(3) Ventilators provide three kinds of tracings: stream, pressure, and volume. All standards are readily branded directly on the ventilator screens using mL/min, cmH2O, and mL, respectively. Newer generations of ventilators bought from Ventilator Dealers can also deliver a combination of fixed and variable streams in the use of dual styles such as volume-assured pressure support and pressure augmentation. The cycle stage is a purpose of the preset inspiratory time and preset tidal capacity (or flow over time to transport a targeted tidal volume). The baseline pressure may be zero (pressure is not raised between sniffs) or raised above zero to a positive pressure that is detained in the lungs by the action of the exhalation valve in the ventilator. When pressure is supplementary it is called Continuous Positive Airway Pressure (CPAP) when providing non-invasive sustenance or Positive End-Expiratory Pressure (PEEP) when providing invasive support (ie the patient has an endotracheal tube or tracheostomy tube).


Specification of ICU Ventilator:


Respirational Rate (RR) (sniffs per minute): between 6 – 40. Note that the little RRs of 6 – 9 are only appropriate for Support Control.


Tidal Volume (TV) (air capacity pushed into the lung): between 200 – 800 mL founded on patient weight.


I/E Proportion (inspiratory/expiratory time proportion): suggested to start around 1:2; best if adaptable between the range of 1:1 – 1:4*.


Assist Switch is founded on Activate Sensitivity: When a patient tries to stimulate, they can reason a dip on the order of 2 to 7 cm H2O, concerning PEEP pressure (not essentially equal to atmospheric pressure).


  • Airway pressure must be observed repeatedly. Maximum pressure must be restricted to 40 cm H2O at any time

  • Plateau pressure must be restricted to max 30 cm H2O.

  • The use of an inert motorized blow-off valve fixed at 40 cm H2O is powerfully suggested. This is combined into most physical resuscitators.

  • Clinicians need interpretations of plateau pressure and PEEP.

  • PEEP of 5–15 cm H2O obligatory; many patients want 10–15 cmH2O.

  • Failure circumstances must consequence in an alarm and permit change to manual clinician override, i.e. if involuntary ventilation fails, the change to immediate ventilation must be instant.


Ventilator Modes

For most patients receiving bellicose mechanical ventilation, either a preset tidal capacity is used (called volume-controlled ventilation, VC) or a preset pressure is used (named pressure-controlled ventilation, PC) to distribute a breath. Note: inspiratory flow in VC can be nominated by the worker to be either square or decelerating. The inspiratory stream in PC is always slowing- a square flow pattern cannot be carefully chosen. Either of these mechanisms can be set up using constant mandatory ventilation (CMV) or irregular mandatory ventilation (IMV). 


With the CMV method anytime the patient activates the ventilator supplied by the ventilator suppliers to get a sniff the ventilator distributes the sniff by either giving the pre-set capacity in VC or the pre-set pressure in PC. In CMV, no decently impulsive breaths occur. With the IMV method, the patient can respire instinctively in between the obligatory breaths then when the time comes for an obligatory breath to occur the ventilator will deliver the mandatory breath. Patient effort can result in differences in spontaneous breaths. So the rudimentary method to give a breath can be given by four basic styles: VC-CMV, VC-IMV, PC-CMV, or PC-IMV.