How does a blood gas analyzer work?

by Anisha Patil HPD

Blood Gas Analyzers extract blood from the needle and measure pH and the partial pressures of oxygen and carbon dioxide. The bicarbonate absorption is also computed. These consequences are usually obtainable for clarification within five minutes. Blood gas examinations can notify health care professionals about the breathing and metabolic status of their critically ill patients by measuring pH, carbon dioxide (pCO2), and oxygen (pO2), as well as electrolytes, lactate, and hemoglobin. Blood gas analyzers made by Blood Gas Analyzer Manufacturers can deliver outcomes on 19 different parameters in just 35 seconds on very small blood examples of only 65 µL.


What are the sensors used in these Blood Gas Analyzers?

Today’s blood gas sensors are the outcome of many years of gradual developments and optimizations. The operating philosophies behind sensor technology have largely remained unaffected, even though the scope of analyzers and thus of sensors has diminished remarkably. Though, miniaturization has fashioned a new challenge: to fit sensor technology into the limits set by the rudimentary sensor design necessities. Most blood gas analyzers supplied by Blood Gas Analyzer Suppliers position multiple-use sensors situated in complicated flow cells. The fluids and gases flow over the sensors in drawn-out, and sometimes almost unfathomable, measurement cycles.


The actual attainment of the sensor signals essential to calculate the readout of a given sensor takes place only during a small portion of the time required for a complete measurement cycle. In the remaining part of the measurement sequence, the analyzer works to find a good starting point for the next measurement. Thus, very little time is selected for the sensor reply, and therefore the sensors should be as fast as likely.


Preferably, they must be so fast that they can reach evenness within the signal-acquisition period. In the real world, this can be attained only in rare circumstances for some sensors, and in the case of the pCO2 sensor, one finds that even the fastest sensor will still be altering (slightly) during the signal acquisition. In these circumstances, it becomes necessary to be able to compute the endpoints of the answers, i.e. extrapolate what the signals would have been, had they been permitted to reach their final values.


Such forecasts must preferably be made based on a mathematical model of the sensor, but can occasionally also be done empirically. In the circumstances where mathematical models are used, one often finds that the sensor replies follow simple mathematical terminologies such as an exponential purpose or maybe sums of two such functions.


Instructions on Overhaul and Upkeep

Though blood gas analyzers bought from Blood Gas Analyzer Dealers are intricate and at times daunting instruments, once the machine is assessed by its subsystems, upkeep is relatively straightforward. The following instructions will support in upholding these machines:

  • Practice good lab methods. Note how the engineer handles and presents the example into the analyzer with little or no disparity in the method. This guarantees reliable outcomes and evades retesting of samples and controls. Practice reflecting and carrying out routine user upkeep on the analyzer to become conversant on the assembly of the various units.


  • Check the operation and maintenance guides to become acquainted with the fluidic plumbing schematics, electronic signal processing trips, and electro mechanical sub assemblies. Check the upkeep procedures and the obligatory PM tasks related to the analyzer. Start with the simple upkeep errands and work up to more intricate PM requirements as experience authorizes.