Ensuring the safety of the building is essential. However, one must put the best to ensure that the building must remain safe from any fire hazards. In older facilities, it’s not uncommon to have a lot of repairs. Further, with the time, these fire dampers Ireland or their parts may damage because of their exposure to the outer elements. However, in case of not taking care of these elements, your damper may get damaged. It may even fail during the inspection. If you are still not aware of the reasons behind the failure of the dampers, then the current post will give you a comprehensive study.

Faulty Actuators

A primary reason behind the failure of the damper inspection is the faulty actuators. Actuators activate the dampers pneumatically or electronically when the smoke is detected. Remember that for the right operation, the pneumatic actuator needs the air. On the other hand, electronically controlled actuators can’t work during a power cut. The faulty actuators can be replaced but after the inspection of reputable fire contractors. Further, these inspection companies keep extra actuators that can be replaced during the inspection.


Rust or Corrosion

These dampers are constructed of metals. Further, the parts such as nuts and bolts are also made of the metals. Over time, these materials will likely get the corrode or rust. Such rust and corrode will stop the dampers from opening or closing. Therefore, you can understand that the corrode may create a problem for the proper action of the fire dampers. It is one of the essential matters for the fire dampers Ireland to take care of while you are sending it for the inspection.  

Fusible Link with Damage

The fusible link is something that keeps the fire damper open. However, at the temperature of 1650F or higher, it gets melt and closes the damper to prevent the fire or smoke from spreading one chamber to another. However, over time, the fusible link may also get damaged and failed to work at the time of emergency. Hereby, the fire inspection professional must check this thing to ensure that all is working well. Else, your damper may get failed in the inspection.

Physical Damage

While working around the other areas of the damper, there is a possibility of the damage to the damper too. When addressing other issues above the ceiling, dampers are likely to be walked on, bumped into, or bent out of place. It may alter the shape of the damper frame, throwing off the alignment of the damper and inhibiting the damper to fully close. Often it affects the operations of the fire dampers Ireland. Therefore, one must ensure that all these physical damages must be taken care of.

Final Words

Therefore, over in this article, you have seen why the fire dampers fail the inspection. It is crucial that before the scheduled inspection of the authorities, you must ask the expert fire inspection companies to identify the issues and resolve them before the final inspection.