Do You Know Why Your Fire Damper Failed?
by Mihai B. Fire Prevention ExpertEnsuring the safety of the building is
essential. However, one must put the best to ensure that the building must
remain safe from any fire hazards. In older facilities, it’s not uncommon to
have a lot of repairs. Further, with the time, these fire dampers Ireland or their parts may damage because of their
exposure to the outer elements. However, in case of not taking care of these
elements, your damper may get damaged. It may even fail during the inspection.
If you are still not aware of the reasons behind the failure of the dampers,
then the current post will give you a comprehensive study.
Faulty Actuators
A primary reason behind the failure of the
damper inspection is the faulty actuators. Actuators activate the dampers
pneumatically or electronically when the smoke is detected. Remember that for
the right operation, the pneumatic actuator needs the air. On the other hand,
electronically controlled actuators can’t work during a power cut. The faulty
actuators can be replaced but after the inspection of reputable fire
contractors. Further, these inspection companies keep extra actuators that can
be replaced during the inspection.
Rust or Corrosion
These dampers are constructed of metals.
Further, the parts such as nuts and bolts are also made of the metals. Over
time, these materials will likely get the corrode or rust. Such rust and
corrode will stop the dampers from opening or closing. Therefore, you can
understand that the corrode may create a problem for the proper action of the
fire dampers. It is one of the essential matters for the fire dampers
Ireland to take care of while you are sending it for the
inspection.
Fusible Link with Damage
The fusible link is something that keeps
the fire damper open. However, at the temperature of 1650F or higher, it gets
melt and closes the damper to prevent the fire or smoke from spreading one
chamber to another. However, over time, the fusible link may also get damaged
and failed to work at the time of emergency. Hereby, the fire inspection
professional must check this thing to ensure that all is working well. Else,
your damper may get failed in the inspection.
Physical Damage
While working around the other areas of the
damper, there is a possibility of the damage to the damper too. When addressing
other issues above the ceiling, dampers are likely to be walked on, bumped
into, or bent out of place. It may alter the shape of the damper frame,
throwing off the alignment of the damper and inhibiting the damper to fully
close. Often it affects the operations of the fire dampers Ireland. Therefore, one must ensure that all these
physical damages must be taken care of.
Final Words