by Generator D. Diesel Generator

 

Description and Function of the Volvo System Components

 

 

Description and Function of the System Components

 

Anti-icing vessel

 

The aim of the anti-icing device and the anti-icing vessel is to provide the compressed air with anti-icing fluid. The anti-icing fluid mixes with any moisture in the compressed air, prevents the fluid mixture from freezing and allows it to be drained off.

 

Function

 

When the compressor charges the braking system a partial vacuum is formed in the anti-icing vessel that allows it to draw air through an inlet in the vessel housing.

 

 

This inlet air is led via a tube down into the anti-icing fluid. When the air rises through the fluid in the form of bubbles it carries with it evaporated fluid to the upper part of the vessel. The air and the evaporated fluid is then drawn through a pipe to the compressor inlet and thus enters the braking system.

 

 

 

Single tower dryer, function

 

Charging phase

 

Air is forced from the compressor (1) to the air dryer inlet (2).

 

From here, the air passes through the drying agent in the vessel (3). The drying agent comprises porous balls called zeolites that have the ability to remove moisture from air. The dried air is then forced through the outlet (4) to the dry tank (5) and then on to the primary tank (6).

 

Cycle phase

 

When the compressed air system has reached full operating pressure, the pressure regulator (7) opens in answer to an air impulse from the drain valve (8) in the air dryer. The dry air from the dry tank (5) then blows back to the air dryer through the drying agent and carries with it any condensate out through the drain valve (8). A check valve (9) prevents air in the primary tank from flowing back to the air dryer when it cycles. There is a heating coil around the drain valve controlled by a thermostat. The heating coil prevents ice from forming in the drain valve.

 

 

Pressure regulator

 

There are different types of pressure regulator depending on the type of air drying system and compressor used in the installation. In installations with an anti-icing system that includes an alcohol vessel, or installations where small air volumes are used, we recommended that a pressure regulator

 

(1) with dump valve be installed. This is done to prevent air from recirculating back to the compressor

 

(2) and being heated. This shortens compressor life.

 

1 Pressure regulator

 

2 Compressor

 

3 Anti-icing injector

 

4 Check valve

 

5 Wet tank

 

6 Safety valve

 

7 Drain tap

 

8 Safety valve

 

NOTICE! If an air dryer is used in the installation, a dump valve is usually included in the air dryer system.

 

 

 

Pressure regulator

 

For use together with anti-icing injector:

 

1 Inlet from compressor

 

2 Outlet to wet tank

 

3 Dump outlet

 

4 Piston

 

5 Control impulse from wet tank

 

6 Check valve

 

7 Dump valve

 

 

Safety valves

 

The compressed air system must be equipped with a number of safety valves in order to protect the system against excess pressure (refer to the Design and Function of the Compressed Air System page 120 section in this chapter). Safety valve opening pressures vary depending on the parts they are protecting and the type of compressor the vehicle is equipped with. The objective of the valve (9) is to protect the compressor from excess pressure. Valve 9a is installed on the primary tank.

 

 

 

Safety valve, function

 

 

 

Pressure from the part of the system the valve protects reaches the safety valve via the inlet (1). When pressure exceeds valve opening pressure a passage between the inlet (1) and the outlet (3) is opened by a ball (2) that compresses a spring (4) and allows excess pressure to escape to atmosphere.

 

 

Drain valve for compressed air tank

 

All compressed air tanks must be fitted with manual drain valves to allow condensate to be drained. The tanks must be drained regularly in order to check air dryer function and to avoid any moisture ingress in the braking system. Condensate must be drained daily on vehicles with anti-icing devices.

 

Compressed air tank

 

Air from the compressor is stored in compressed air tanks and is deli