Recently,some OBD360 customers feedback  that they have purchased the Xtool x100 pad2 tablet key programmer on our site. But they met a battery problem. For example, One customer left it fully charged and 1 day later, when he tried to use it and it was dead.Also he noticed that the battery drains very quickly while in use, from 100% to 70% in about 15mins. They dont know how to solve this problem, and ask us for help.

After feedback problem to Xtool factory, we have got final Solution from Xtooltech engineer to solve this X100 PAD2 Battery Drain and Power off problem:
Tools required:
1pc* Static bracelet
1pc* Hot air gun  (350±10℃ Temperature setup: 350±10℃)

Precautions: Please wear the static bracelet before each operation.

Procedure 1:  Change C6 capacitor
Position: C6
Name: Chip capacitor
Chip specification: 4.7UF/10V  0603
1.Disassemble the C6 capacitor and desolder a 4.7K 0603 resistor



Procedure 2: Remove transistor
Position: Q14




Name: S8050
Chip specification:  0.1uF/50V 0402
1.Disassemble the Q14 transistor.
Procedure 3: Change C123 capacitor
Position: C123
Name: Chip capacitors
Chip specification:  0.1uF/50V 0402
1.Replace the C123 capacitor with a 3.3K%5  0402 resistor.


More products about XTOOL,check here:
http://www.obd360.com/wholesale/original-xtool-diagnostics/ 

Sponsor Ads


About Launch Creader Freshman   Auto Workshop

4 connections, 0 recommendations, 29 honor points.
Joined APSense since, November 20th, 2018, From Tukwila, United States.

Created on Apr 9th 2019 20:03. Viewed 362 times.

Comments

No comment, be the first to comment.
Please sign in before you comment.