Things Every ULC Certified Fire Alarm Monitoring System Needs

by James Lott Freelance writer
Underwriters Laboratories of Canada (ULC) has launched a criterion that alarm companies must follow to be tilted for fire alarm monitoring. This standard equips guidance and necessities for power supplies, reaction times, staffing, security grades, etc.

ULC lists alarm companies to comply with ULC criteria and nationally acknowledged regulations. Once a business moves through this evaluation procedure, it can issue certifications within its listing classification. These certificates are generally given when required by a requesting body to ensure adherence to national standards. This site encloses the records needed to qualify for inspection and the necessary forms to request certificates. 

There are some major things that every ULC fire alarm monitoring system requires.

1. A ULC-Listed Fire Alarm Monitoring Transmitter
Every ULC fire alarm monitoring facility must contain a transmitter tested to confirm it relents with the ULC fire alarm monitoring system standard ULC-S559. This standard ensures that the gear used in any ULC fire alarm monitoring system structure can send an alert to the signals accepting centre within a minute and prioritizes alarms based on the classification. This is not identical to your common fire alarm system.  
 

2. A Fire Sprinkler System
The monitoring transmitter must be attached to a fire sprinkler system to monitor a structure to satisfy the ULC-S561 fire alarm monitoring standard. This means that the system is established according to the relevant criteria in the fire regulation and building principle and is preserved according to those codes.  

3. A Source of communication
A ULC fire alarm monitoring cannot send direct signals to an SRC on its own; it requires approved forms of transmission to get alerts to the monitoring station. Standard methods of transmission can contain a phone line and the internet. Whether or not you require one or additional forms of communication relies on the ULC fire alarm monitoring system set up.

4. ULC Fire Alarm Monitoring Needs Devoted Power Source
The ULC fire alarm monitoring transmitter requires its own power source to issue the ULC Certificate. This electricity source is usually a 120VAC energy source and is only devoted to the fire alarm monitoring transmitter. If you have a separate energy source, such as a fuel generator, connecting your ULC fire alarm monitoring transmitter would be perfect.

5. Requires Regular Inspection
ULC fire alarm monitoring systems are needed to regularly inspect the ULC fire alarm monitoring transmitter, such as wire conductance, battery capacity, communication times and more. This guarantees that the alarm system is in good operating condition and periodic assessments help reduce false alarms.  

6. A ULC-S561 Certificate
A ULC-certified fire alarm monitoring system cannot be considered a genuine ULC-certified fire alarm monitoring system if it doesn't have a certification administered stating adherence with ULC-S561. This guarantees that the whole monitoring system is obliging with ULC-S561, including the installer and the SRC. 


What Does a ULC Certification Provide?

A ULC Certification proves to Authorities Having Jurisdiction (AHJ) and insurance organizations that your monitoring system has been installed, inspected and retained to the highest standard.

Once a monitoring company is certified, the ULC records them to reveal their compliance with ULC standards. Only once a monitoring company meets its evaluation procedure will it qualify to issue ULC certificates. 

Although most fire divisions have adopted and acknowledged the CAN/ULC-S561 fire alarm monitoring standard, you may still encounter monitoring providers who do not meet the necessities of this standard. As a client, it is strongly advised that you must ask for a ULC certificate when installing a fire alarm monitoring system.


Benefits of ULC Certificates

  1. ULC Certificate reveals that the installation is checked and sustained by the Listed alarm service organization.
  2. A requirement is that all program parts are in position, and the system is contained in the ULC database.
  3. Third-party auditing of businesses in the schedule impacts all parties' playing level and delivers a comfort level that ULC is auditing alarm organizations.
  4. Understanding that alarm and monitoring organizations are being audited enables insurance firms and regulatory management to determine their workforce involvement in monitoring and approval of companies.
  5. ULC will explore any problems with certificates or recorded alarm companies and report to the certificate needing body.
  6. Once an examination is conducted to evaluate compliance with relevant program necessities and Canadian National Standards, the alarm firm is then ULC listed and certified to issue ULC certificates to those premises that concede with the essentials for the specific service category.