Rhyolite crusher price in Brazil
Infrastructure foundation wall and the wall should be disturbing
force in a direction parallel to the crusher, the wall thickness ratio
at this time should not be greater than 6; such as a wall perpendicular
to the direction of disturbing force, its high-thickness ratio of not
more than 4. When meet the above requirements, the wall can be
constructed of reinforced, otherwise shall be calculated reinforcement.
Foundation of massive volume of less than 40m³ in general may not be
reinforced, structural steel configuration only weaken parts of the hole
or opening and the top surface of the actuator. Wall basis and
foundation of massive cantilevered portion of the base wall and roof
beam frame basis are calculated should be reinforced.


Dynamic
calculation includes a base set of calculation from the maximum
amplitude vibration frequency and amplitude, top of the foundation shall
not exceed the allowable value of existing norms. When two or more
crusher setting on the same basis, disturbing force and torque whichever
scrambling absolute value sum, calculated by multiplying the amplitude
reduction factor of 0.75 can. For the calculation results can better
meet the actual situation must be carefully chosen foundation stiffness
and dynamic computing model. Higher than the wall thickness of less than
or equal to the base wall 4, according to the basis of massive
computing power. In addition, all should be calculated on the basis
frame. To avoid the crusher may start and stop the resonance occurs, the
base should be set higher than the natural frequencies of the crusher
operating frequency.