Prostar PHP60K igbt 60kva 3 phase ups data center power solutions

by Orson Z. Overseas Trade Manager

Prostar PHP60K igbt 60kva 3 phase ups data center power solutions provides battery backup and AC power protection against power disturbances that can damage electronics or destroy data. It’s recommended for critical IT or corporate infrastructure, telecom, LAN/WAN, security and emergency, financial and light industrial applications.

True online double conversion igbt 60kva 3 phase ups is specially designed with pluggable power module and front access to simplify maintenance.

Output power factor 1 true igbt 60kva 3 phase ups is non-isolated, redundant, scalable, 3 Phase Online UPS power protection system designed to cost effctively provide high levels of availability.

Voltage and Frequency Independent (VFI) design allows continuous operation at any supported voltage at either 50 or 60 Hz. Zero transfer time to battery mode ensures no disruption to the attached loads. Automatic and Manual Bypass keeps connected equipment powered even during overloads and UPS maintenance.

Prostar High Frequency 3P 3P Online UPS 30KVA 60KVA 100KVA 120KVA 180KVA 200KVA

60KVA 3 Phase UPS Features & Benefits

1. True On-Line Double Conversion 3 Phase

  • Provides fully regulated sine wave AC output for critical telecom, network, security, financial, corporate and light industrial applications
  • +/-1% output voltage regulation in online and battery modes
  • Output power factor 1 is allowing for more connected devices
  • Selectable 380/400/415V output voltage
  • Wide input voltage window (190V–478V) minimizes battery use and prolongs battery life

2. IGBT Inverter Technology

  • Produces output power with less than 2% THD to keep connected equipment functioning at its peak
  • Low <4% THDi input rating and advanced IGBT rectifier

3. Modulity Design

  • Pluggable power module design
  • Front access design for esay maintenance

4. Paralleling Capability

  • Connect up to 6 units in parallel configuration for increased capacity and fault tolerance

5. Automatic and Manual Bypass

  • Manual bypass switch as well as an automatic bypass function ensures 100% availability of connected equipment by safely passing through AC power when the power module requires maintenance

6. ECO Mode

  • Operates at efficiency levels as high as 99% when input line conditions are favorable

7. SNMP/Web Capability

  • Slot for SNMP card network interface or AS400 relay card for remote monitoring and control options

8. Small-Footprint Tower Design

  • Reduced-size black tower case saves valuable floor space
  • Matching external battery cabinets enable extended runtime

Uninterruptible Power Supply Details

Prostar PF1 3 Phase High Frequency Online UPS Front View

3 Phase PF1 Online UPS 100KW 120KW Rear

3 Phase Online UPS 100KVA – 120KVA Rear

Specification

ModelPHP60K
Capacity60KVA/60KW
NoiseLess than 70 dB @ 1 Meter
Dimension(WxDxH mm)815x300x1000
Weight(Kgs)74
INPUT
Nominal Voltage3 Phases 4 Wires, 380Vac/400Vac/415Vac
Voltage Range110Vac – 300Vac @50% load; 176-276Vac @100 load
Nominal Frequency50Hz/60Hz (Automaticly)
Frequency Range40Hz – 70Hz
Power Factor>=0.99 @100% load
Harmonic Distortion(THDi)< 4% at full liner load
OUTPUT
Voltage3 Phases 4 Wires, 380Vac/400Vac/415Vac ± 1%
Frequency50Hz/60Hz±1%
Frequency Range(Synchronized)46Hz – 54Hz or 56Hz – 64Hz
Harmonic DistortionLinear load<2%, Non-linear load<5%
Overload Capacity100-110% for 60mins, 111-125% for 10mins, 126-150% for 1 min, >150% for 400ms
Crest Factor3:1
Wave FormPure sine wave
Transfer Time0ms
BYPASS
Nominal Voltage380Vac/400Vac/415Vac
Voltage Range305Vac – 457Vac
Frequency Range(Synchronized)46Hz – 54Hz or 56Hz – 64Hz
Overload Capacity>130% 1 min(default); Continously working until breaker protection(optional)
EFFICIENCY
AC Mode96.00%
ECO Mode99.00%
Battery Mode95.00%
BATTERY
Battery TypeDepending on application
Battery Numbers32 – 40Pcs (Adjustable)
Max. Charging Current1A – 18A (Adjustable)
Charging Voltage+/- 13.65V*N (N=16 – 20)
INDICATORS
7 Inch Touch LCD DisplayUPS status, load level, battery level, input/output voltage, discharge time, and fault conditions
SYSTEM
ProtectionInput over-voltage, under-voltage; output overload, shortcircuit; Inverter over-temperature; Battery under-voltage,over-voltage
IP ProtectionIP20
Parallel ModeN+1,N+X,can be in parallel with differenct power capacity
ENVIRONMENT
Operating Temperature0℃ to 40℃
Humidity0~95% (non-condensing)
Altitude0 – 1500m at full load
Safety complianceEN 62040-1:2008; EN 62040-1/EC:2009; EN 62040-1/A1:2013 and Directive 2014/35/EU
EMC conformanceEN 62040-2 and Directive 2014/30/EU
MANAGEMENT
Smart RS-232/USBWindows 2000/2003/XP/Vista/7/8,Linux and MAC
SNMPPower managemetn from SNMP manager and web browser

The Articles You May Like


Sponsor Ads


About Orson Z. Advanced     Overseas Trade Manager

36 connections, 0 recommendations, 179 honor points.
Joined APSense since, April 9th, 2014, From Foshan, China.

Created on Oct 6th 2020 19:43. Viewed 304 times.

Comments

No comment, be the first to comment.
Please sign in before you comment.