by Tricolite02 Duct system suppliers dg synchronization panel

Generator synchronization is a process in which the matching of various parameters such as phase angle, frequency, voltage, sequence, and waveform of the power generator is done with various other power generator sources. This is carried out before a particular power generator is reconnected to a power source. As and when the generator is synchronized keeping in view the above-said parameters with another generator, the system starts working.

 

Poor synchronization creates disturbances in the power framework

 

For perfect synchronization of a power generator with a primary power source, there are different grid specifications in different countries. While manufacturing and supplying these devices, DG synchronizing panel suppliers in India also take grid specifications of different countries into serious considerations. Poor synchronization not only creates so many disturbances in the power framework but also causes various damages to the generator as well as the transient framework. 

 

Some specifications of the panels manufactured by the leading DG synchronizing panel suppliers in India include the following:

 

  • Application- Synchronization of DG Power
  • Reference Standard- IEC:61439-1, 2009, IS:8623
  • Operational Voltage- 110/ 230V AC/DC, 415V AC
  • Control Voltage- 24V/ 110V/ 220V AC/DC
  • Phase/ Frequency - 3 Phase/ 50 Hz
  • Degree of Protection - IP-54/ IP-55
  • Form of Separation - 2b
  • System Automation - DEIF Controller
  • Operational Height - 300mm Min./ 1800mm Max.
  • Max. Height of Panel - 2275mm.
  • Width of Panel - 700/ 900mm.
  • Depth of Panel - 600/ 1000/ 1200mm.

 

Some of the principal terminologies involved and devices needed to carry out the task of synchronization are:

 

Line Voltage Monitor (LVM)

 

It is a special kind of monitoring relay that is heavily utilized to find faults with the availability of the supply in the bus. LVM also has some additional functions such as reverse phase as well as under/over voltage settings.

 

Auto Mains Failure (AMF)

 

Auto mains failure stands for the disconnection of the load from the mains framework in case of power failure.

 

Load Dependent Start/Stop

 

It is an inbuilt feature available in the DG Controllers made and supplied by the leading electrical switchboards suppliers in India. In this, the controller determines the number of DG sets to proceed in the service according to the present load. 

 

Major applications 

 

DG synchronizing panels made and supplied by the leading electrical switchboards suppliers in India are widely used in a large number of industries and fields. Some of them include-

 

  • Telecom Sector
  • Processing plants
  • Engineering units
  • Hospitals
  • Hotels
  • Offices, and
  • Institutions. 

 

Concluding Remarks

 

Tricolite is one of the leading DG Synchronization Panel suppliers in India. The panels made and supplied by the company comply with the requirements of standard IEC: 61439-1, 2009 and IS: 8623. The company has always been at the forefront of innovation in advanced and efficient DG Synchronization Panel making.  

 

The manufacturing facility of the company is equipped with ultra-modern CAD/CAM technology and also specifically customized technology that includes Elecdes, Pro-E, Solid Edge, Primavera, AP100, Biloma & ESMS. Tricolite has always focused on designing future-ready as well as smart products that can assist its customers in analyzing their energy consumption trends. The company has proven its mettle in designing and developing fully customized products as per the specific requirements of its customers.  


Sponsor Ads


About Tricolite02 Duct system suppliers Junior   dg synchronization panel

1 connections, 0 recommendations, 15 honor points.
Joined APSense since, November 6th, 2020, From delhi, India.

Created on Jan 26th 2021 23:19. Viewed 248 times.

Comments

No comment, be the first to comment.
Please sign in before you comment.