Understanding The Importance of Air Handling Units in Office Spaces
by Rudra S. ConsultantAn Air Handling
Unit (AHU) is a critical part of a building’s air conditioning system. It is
designed to cool down bigger spaces and also helps in ensuring optimum Indoor
Air Quality (IAQ). Each structure may have several AHUs and the quality of the
air that prevails in an office space depends largely on the overall functioning
of the AHU and its related elements. Another important thing is how properly is
the AHU upheld. Many times, it remains a neglected part of a HVAC system
workers which cause poor IAQ issues inside the workspace.
Due to the
outbreak of COVID pandemic, it has become important than ever for HVAC workers
to understand the importance of Air Handling Units (AHUs) in office spaces and
their maintenance in delivering optimum indoor air quality. According to a
leading Air Handling Unit manufacturer in India, the rise in Covid infections
were primarily seen in office spaces where AHUs were not maintained properly.”
Basics of AHU
Design
The formula that
it primarily used in this domain is Q=1.1 x CFM x T, in which Q refers to the
sensible load, T means the temperature variation between the incoming and outgoing
air supply, and CFM refers to the volume of air that is meant to be supplied
for keeping a particular temperature. All these elements can be used to find
out the amount of air that circulates to eradicate the sensible heat. The
conversion aspect for the atmospheric pressure under which the AHU takes charge
is 1.1, with 1.1 denoting to operations at sea level.
The air velocity
over the heat transfer exteriors plays an important in regard to the design of
cooling coil. The coil will be smaller and the pressure drop will be greater as
the velocity goes up. The opposite is true when coil velocity is brought down.
The fan size tends to be affected by the stated velocity, which will then have
a say on the amount of energy that AHU utilizes.
The filtration
system in use greatly affects how perfectly the AHU takes charge since filters
are the heart of the AHU because they prevent dust and other pollutants from
entering the office environment. Aerosols, which include contaminants including
dust, mites, smoke, and others, are gauzed in unit of microns (micrometre).
Controlling
Capacity of AHUs
A workspace's
heat load tends to change throughout the daytime which takes place due to the
prevailing changes in occupant density along with the external loads such as
temperature variations. Hence, a method to determine capacity management
becomes crucial to ensure that the workplace is cooled in a seamless manner. An
AHU manufacturer in India can choose from the following techniques for this:
• Installing a
bypass line between the chilled water ingestion and outward paths to change the
flow of chilled water over the heat exchanger. The charge on the bypass line is
managed by experts to allow the passage of more (when room temperature is on
the upper end) or less (when room temperature is at the lower end) water to the
heat exchanger given the incoming room temperature.
• By controlling
the volume of the air going to the room through a damper, chilled water has been
found to maintain a uniform temperature. Depending on the temperature of the
return air, the damper opens or closes accordingly.
• The CFM is modified
dependent on room temperature through the placement of a Variable Frequency
Drive (VFD) on the Fan motor. Considering the power consumption changes as a
cube of the motor speed, this is undoubtedly the most viable approach to change
the capacity.
Maintenance
of AHUs
Comparatively
speaking, maintaining the AHU is easier than maintaining other, more complicated
building equipment. The following are important considerations for AHU
maintenance:
• Filter health,
which includes checking for any damage to the filtering surface as well as the
requirement for clean filters. The differential pressure between the filter's
input and exit is a metric used to assess the filter's condition.
• Air flow
measurement helps in ascertaining the condition of the Fan as well as the
filters. The CFM value during operation when compared to the design values will
give the maintenance team an idea of how the whole AHU is running
• As the air
from AHUs gets into the office environment, cleanliness becomes crucial. In a
bid to prevent the AHU rooms from being utilised as warehouses, the HVAC
handlers should make sure they remain free from dust and other contaminants.