(9) Coolant temperature too low

 

 

 

Fault feature

 

 

Possible cause

 

Correction

 

 

 

Low ambient temperature, low load.

 

 

Increase load to a proper degree.

 

 

The reading of water thermometer is not correct.

 

 

Regulate or replace the thermometer when required.

 

 

The thermostat does not work well or was damaged.

 

 

Replace the thermostat.

 

(10) Oil in coolant

 

 

 

Fault feature

 

 

Possible cause

 

Correction

 

 

 

Damage of the oil cooler core.

 

Replace the oil cooler core.

 

 

Fault of the cylinder head gasket.

 

 

Replace the gasket.

 

(11) Electrical system fault

 

 

 

Fault feature

 

 

Possible cause

 

Correction

 

 

Starting motor does not work.

 

 

 

(1) Poor contact of the connecting wires.

 

(2) Poor contact of the electromagnetic switch.

 

(3) Poor contact of the electric brush.

 

(4) Short-circuit of the starting motor.

 

(5) Poor electric charging or the capacity of battery too small.

 

 

Clean and tighten the terminals or joints.

 

Check the switch contactor and grind it by sandpaper.

 