Articles

Information about Volvo Engine TAD734GE

by Generator D. Diesel Generator

 

 

Information about Volvo Engine TAD734GE

 

The DU is an computerized instrument panel which shows engine working values on an LCD screen. In the display it is possible to show multiple windows with different information, i. g. Volvo engine rpm, coolant temperature, fuel consumption and fault messages.

 

At start up, the display performs a self-test. If an constant signal is heard, the system has discovered a malfunction. The display will work but may act in an unexpected way.

 

The DU is connected between the engine control unit and the CIU or DCU.

 

Contrast

 

In the display modes Engine, Trip and Graph, it is possible to adjust the contrast. Press button 5 outside the menu and then + (button 4) or - (button 3) to adjust the contrast.

 

Contrast.jpg

 

 

 

Engine

 

Rpm and coolant temperature is shown in the upper part of the display. In the lower part it will show trip computer and a fuel level indicator, if these functions are installed.

 

Coolant.jpg

 

 

 

Multi

 

In the multi mode, button 2, the information can be shown in four windows, analogue or digital. The display toggles between the two when button 2 is pressed repeatedly. By pressing button 5, the right arrow, you choose what information to be shown in the different windows. Press repeatedly on the button that correspond to the window, until desired information is shown.

 

 

 

Multi.jpg

 

 

 

Trip

 

To display the trip computer press button 3, Trip

 

Trip Fuel, since last reset

 

Fuel Rate, fuel consumption

 

Trip hours, since last reset

 

Engine hours, total amount of operating hours

 

Reset by pressing button 3 for three seconds until a beep is heard.

 

Trip.jpg

 

 

 

Graph

 

The information is shown as graphs. Press button 4 repeatedly to choose what information will be shown. The time interval is set in the Configuration menu.

 

If the connection is broken there will be a straight line in the display.

 

Graph.jpg

 

 

 

Configuration menu

 

Press button 5 for three seconds to enter the Configuration menu. Navigate with the up and down  arrows, select with the right arrow.

 

Configuration menu.jpg

 

 

 

Units

 

- PRESSURE: kPa, PS

 

- VOLUME; LITRE, GAL, Imperial GAL.

 

Fuel rate is adjusted according to volume unit, L/H, GAL/H, IGAL/H.

 

- TEMPERATURE; °C, °F

 

Units.jpg

 

 

 

Alarm Status

 

List of active alarms, refer to Reading fault codes via the DU (Display Unit)

 

Alarm status.jpg

 

 

 

Settings

 

LANGUAGE; setting of what language is to be used in the display.

 

BLEEP; On/Off, setting if pressing the instrument buttons will be followed by a beep or not.

 

DISPLAY; setting of ENGINE RPM gauges RPM ENGINE, 2500-9000 RPM, in steps of 500

 

RPM


Sponsor Ads