Cummins Power Generation Engine Introduction and Operation

Cummins Product
Introduction
Provide customers with a
complete set of power packs suitable for generator set application. All power
pack components are designed and validated in accordance with Cummins design
and development standards. The products include:
Cooling system: mainly
include radiator and pipe assembly. Provide customers with radiators suitable
for high temperature, extreme cold, high altitude, high corrosion and other
special environments.
Speed control system:
mainly include speed controllers and ECM electronics control module. Provide
customers with a variety of speed regulation schemes to meet the operating
requirements of different levels of power station.
Air intake system:
mainly include air filter and its pipelines. Twin-stage filter element is
adopted and the filtration effectively is up to 99.5%, which can prevent the
abnormal engine wear and provide customers products suitable for the special
environment of high altitude, high dust and high humidity.
Proper
Use of the Engine
1. Ensure engine
operation environment is safe and reliable, and the components are tightly
connected.
2. Check coolant level,
oil gauge, and discharge water from oil-water separator for the first time.
3. Make sure there is no
interference damage to the belt fan and no abnormality in the inlet and exhaust
system.
4. The start-up time of
the starter should not exceed 15 seconds, and the continuous start should be
separated by 2 minutes. If the engine fails to start three times in succession,
the fuel system should be checked first.
5. After starting,
observe the change of oil pressure within 15 seconds. If the oil pressure does
not show up within 15 seconds or the pressure value is lower than 69 kPa, shut
down immediately to avoid engine damage.
6. After the first start
of each day, the engine should be warmed up at a low speed for 3-5 minutes.
When the temperature is below 0°C, the engine must be warmed up to ensure
sufficient lubrication of engine parts and stable oil pressure.
7. Start the engine
after passing the inspection.
Correct
Operation of the Engine
1. Do not make the
engine idle too long, idling too long (more than five minutes) may damage the
engine.
2. Check oil pressure,
cooling temperature and other engine parameters through the control panel of
the genset to ensure that the engine is working properly. If there is alarm
information on the panel, please take measures to correct the alarm status.
3. Check oil pressure
gauge and coolant temperature values frequently. If pressure or temperature
does not meet the technical specifications, stop the machine immediately.
4. Continuous operation
of the engine at coolant temperatures below 60°C or above 100°C can damage the
engine.
5. Avoid engine overload
or long-term no-load operation. This type of practice is considered to be
improper use of the engine.
Cummings is the world's
leading manufacturer of power equipment that designs, manufactures and
distributes engines and related technologies including fuel system, control
system, inlet air treatment, filtration system, exhaust gas treatment system
and power system, and provides after-sales services.
Cummins has eight joint
ventures in China. DCEC Cummins mainly produces B,C,L Series diesel engines for
power generation and CCEC Cummins mainly produces M, N, K series diesel
engines.
Starlight Power is authorized
as Cummins diesel generator OEM. We can provide 20KW to 400kw DCEC Cummins
generator and 200KW to 1500KW CCEC Cummins diesel generating sets with various
types.
Post Your Ad Here