How to Remove and Install JCB 520 Excavator Blower Unit
by Dave Jack Auto Car Repair KnowledgeThe blower W is located inside the HVAC/air conditioning unit and can
be removed without having to remove the HVACunit from the machine
The only user-serviceable part is the resistor which determines the
blower motor speed. Other faults, excluding wiring faults, necessitate
the replacement of the blower unit complete.
2017 JCB Service Parts Pro + 2017 Service Repair
2020 JCB ServiceMaster 4 v1.88.3 Download & Installation
Resistor replacement requires the removal of the blower unit as follows:
Removal Disconnect the battery.
Gain
access to the HVAC unit by removing the right hand side console and
remove the HVAC unit top cover,refer to HVAC/ Air Conditioning Unit -
Removal and Replacement Steps 2 and 3.
3
Disconnect the electrical connections to the blower.
4
Remove the screws securing the blower unit to the HVAC unit housing.
5
Carefully withdraw the blower from the HVAC unit.
6
To
remove the resistor, disconnect the electrical connections and unscrew
the resistor. Replacement is the reverse of the removal procedure
Freeze Protection Thermostat
- Removal and Replacement
The Thermostat V monitors the external temperature of the evaporator and is located inside the HVAC/air conditionig unit.
Removal
1
Disconnect the battery.
2
Gain
access to the HVAC unit by removing the right hand side console and
remove the HVAC unit top cover, refer to HVAC/ Air Conditioning Unit -
Removal andReplacement Steps 2 and 3.
3
Unclip the sensor wire from the evaporator and gently remove the wire from between the fins.
4
Disconnect the electrical connections to the thermostat.
5
Remove the screws securing the thermostat to the HVAC unit housing.
Replacement is the reverse of the removal procedure.
Evaporator Matrix
- Removal and Replacement
Note: Before removing the Evaporator Matrix, discharge the system.
Refer
to Conditioning - Refrigerant Charging and Discharging. The evaporator
matrix S is located inside the HVAC/air conditioning unit and can be
removed without having to remove the HVAC unit from the machine.
Removal
Removal
of the evaporator matrix will require the assistance of a refrigeration
engineer or suitably trained person since the refrigerant needs to be
drained from the system.
2020 JCB ServiceMaster 4 Free Download for Win XP,Win 7,Win 8,Win 10
Disconnect the battery.
Gain
access to the HVAC unit by removing the right hand side console and
remove the HVAC unit top cover, refer to HVAC/Air Conditioning Unit -
Removal and Replacement Steps 2 and 3.
Unclip the thermostat evaporator and gently remove the wire from between the fins.
The
air conditioning system is a closed loop system and contains
pressurised refrigerant. No part of the system must be disconnected
except by a refrigeration engineer or suitably trained person. You can
be severely frostbitten or injured by escaping refrigerant
Drain the
refrigerant from the unit and remove all pipe work (refrigerant and
air) which will prevent the unit from being withdrawn from the machine.
Check around the top of unit, rear, bottom and right side.
5
Carefully
lift the evaporator matrix complete with expansion valve T from the
housing, bearing in mind that a certain amount of resistance will be met
due to the stiction from the sealing putty. Replacement is the reverse
of the removal procedure.
Sponsor Ads